The following data specifies lighting recommendations to achieve 20 footcandles of illumination per 50 feet of barn length for: Tiestall or Stanchion Barn Types

Barn Layout Typical Width (ft) Surface Area to be Lighted (sq ft) 1 Clear Height (ft) 2 Mounting Height (ft) 3 Fixture Make/Model Number Lamp Wattage (Watts) Number of Fixtures Required per 50 ft
2 row tiestall or stanchion 36 1,800 8 3 Metalux/VT-248HO-DR-DL 60 22
8 3 Metalux/VT-296HO-DR-DL 110 10
8 3 Metalux/STN-248HO 60 20
8 3 Metalux/STN-296HO 110 9
10 5 Metalux/VT-248HO-DR-DL 60 25
10 5 Metalux/VT-296HO-DR-DL 110 12
10 5 Metalux/STN-248HO 60 22
10 5 Metalux/STN-296HO 110 10
12 7 Metalux/VT-248HO-DR-DL 60 27
12 7 Metalux/VT-296HO-DR-DL 110 13
12 7 Metalux/STN-248HO 60 25
12 7 Metalux/STN-296HO 110 11
2 row tiestall or stanchion 40 2,000 8 3 Metalux/VT-248HO-DR-DL 60 24
8 3 Metalux/VT-296HO-DR-DL 110 11
8 3 Metalux/STN-248HO 60 22
8 3 Metalux/STN-296HO 110 10
10 5 Metalux/VT-248HO-DR-DL 60 27
10 5 Metalux/VT-296HO-DR-DL 110 13
10 5 Metalux/STN-248HO 60 24
10 5 Metalux/STN-296HO 110 11
12 7 Metalux/VT-248HO-DR-DL 60 30
12 7 Metalux/VT-296HO-DR-DL 110 14
12 7 Metalux/STN-248HO 60 27
12 7 Metalux/STN-296HO 110 12
2 row tiestall or stanchion 44 2,200 8 3 Metalux/VT-248HO-DR-DL 60 26
8 3 Metalux/VT-296HO-DR-DL 110 12
8 3 Metalux/STN-248HO 60 23
8 3 Metalux/STN-296HO 110 11
10 5 Metalux/VT-248HO-DR-DL 60 30
14 8 Lumark/MPBE-5A-175 175 13
16 10 Lumark/MPBE-5A-250 250 10
18 12 Lumark/MPBE-5A-250 250 10
4 row head to head 99 3,950 10 4 Lumark/HPBE-5A-150 150 10
10 4 Lumark/MPBE-5A-175 175 12
12 6 Lumark/HPBE-5A-150 150 11
12 6 Lumark/MPBE-5A-175 175 13
14 8 Lumark/HPBE-5A-150 150 11
14 8 Lumark/MPBE-5A-175 175 14
16 10 Lumark/MPBE-5A-250 250 10
18 12 Lumark/MPBE-5A-250 250 11
6 row head to head 115 4,750 10 4 Lumark/HPBE-5A-150 150 12
10 4 Lumark/MPBE-5A-175 175 14
12 6 Lumark/HPBE-5A-150 150 13
12 6 Lumark/MPBE-5A-175 175 15
14 8 Lumark/HPBE-5A-150 150 14
14 8 Lumark/MPBE-5A-175 175 16
16 10 Lumark/MPBE-5A-250 250 11
18 12 Lumark/MPBE-5A-250 250 12

  • Note 1:  Cow level has been defined as 4 feet above the surface the cow stands on.  The surface area to be illuminated does not include 20 foot wide delivery driveway area for 4 and 6 row drive-through barns.

  • Note 2:  Clear height is the distance from the cow-standing surface to the bottom chord of the building truss or the bottom of a fixture support arm.

  • Note 3:  Mounting height is defined as the distance above the cow level (4 ft) to the bottom of the light fixture.


 Freestall Table      Tiestall Lighting Table 


Home      Background      Studies      Example      Program


Illinois Council on Food and Agricultural Research
If you have any questions or comments please contact:
Illinois-Traill@uiuc.edu
Copyright © 2001- 2004
University of Illinois at Urbana-Champaign
.
All Rights Reserved.
Illinois TRAILL home page